Rice Lake RL75016SS Stainless Steel,Double-Ended Beam Load Cell
General information
Double-ended beam with center loading. Designed for tank and hopper applications. Stainless steel provides protection against corrosive materials. Capacities range from 1,000 lb to 75,000 lb. Complete with 25 ft of load cell cable.
Find out the price or get a consultation
-
Full Scale Output:
3.0 mV/VOutput Resistance:
700 (± 5) ohmInput Resistance:
770 (± 10) ohmMaterial/Finish:
Stainless steelTemperature:
Operating range
0 °F to 150 °F (-18 °C to 65 °C)Seal Type:
Environmentally sealed, IP67Safe Overload:
150% full scaleSafe Sideload:
100% full scaleRated Excitation:
5 to 10 VDC (15 V maximum)Nonlinearity:
0.07% full scaleHysteresis:
0.02% full scaleCable Diameter:
1,000 to 25,000 lb: 0.200 in
50,000 to 75,000 lb: 0.305 in
Polyurethane jacketDeflection at Capacity:
1,000 to 3,000 lb: 0.01 in
5,000 lb: 0.015 in
10,000 to 20,000 lb: 0.022 in
25,000 lb: 0.036 in
50,000 lb: 0.052 in
75,000 lb: 0.07 inInsulation Resistance:
5,000 megohmCable Length:
25 ftCable Color Code:
Red +Excitation
Black –Excitation
Green +Signal
White –SignalWarranty:
Two-year limitedApprovals:
cFMus -


Rated Capacity A1 A2 C D E F lb/in 1,000 to 5,000 0.50 1.25 1.25 1.25 7.50 6.25 10,000 to 25,000 0.81 1.99 1.44 1.94 8.75 7.50 50,000 1.31 3.00 2.44 2.94 13.50 11.50 75,000 1.31 — 2.44 2.94 13.50 11.50 -
Booklet rl75016ss
Call us +38 (0800) 301 770