Designed with the user process in mind and built for communication, Rice Lake’s Performance™ Series weight indicators/controllers are packed with power, yet simple in design. Intuitive multifunction menu keys allow navigation in any application and the NEMA Type 4X/IP69K-rated gasket effectively keeps internal components out of harm’s way. Twenty time- and weight-based setpoints provide ultra responsiveness to handle any process control requirement. For customized operation, use Rice Lake’s intuitive iRite software to program functionality specific to the application. The innovative 880 and 880 Plus also accommodate a wide range of connectivity—from USB and RS-232/ RS-485 to Ethernet TCP/IP.

Install an option card for additional fieldbus compatibility, analog output, relay board, dual serial outputs or 24-channel digital inputs/outputs. With two different enclosure types to choose from, Rice Lake’s 880 Performance Series exceeds your expectations wherever you need it.

Find out the price or get a consultation

  • Power:
    Line voltages: 100 to 240 VAC
    Frequency: 50/60 Hz
    DC voltages: 12 to 24 VDCPower consumption:
    AC: 15 W, DC: 20 W

    Excitation Voltage:
    10 VDC (+/- 5 VDC), 16 × 350 ohm or 32 × 700 ohm load cells

    Analog Signal Input Range:
    -45 mV to 45 mV

    Analog Signal Sensitivity:
    0.3 μV/graduation minimum at 7.5 Hz;
    1.0 μV/graduation recommended

    A/D Sample Rate:
    7.5 to 960 Hz, software selectable

    Resolution:
    Internal: 8,000,000 counts
    Display: 999,999

    System Linearity:
    ± 0.01% full scale

    Digital I/O:
    Four I/O onboard, primary keys, pseudo
    functions, batching functions

    (Optional) Analog Output:
    Voltage output: 0–10 VDC
    Load resistance: 1 k ohm minimum
    Current output: 0–20 mA or 4–20 mA
    External loop resistance: 500 W maximum(Optional) Relay Board:
    Four channel relay module, dry contact 3 A at 115 VAC, 3 A at 30 VDC

    Communication Ports:
    RS-232 full duplex or RS-485 half duplex; USB micro A/B connector 2.0; Ethernet TCP/IP

    Annunciators:
    Gross, net, center of zero, standstill, lb, kg, tare, preset tare, multi-range/interval 1/2/3

    Display:
    LED, 0.56 in (14 mm), six-digit, 14-segment with decimal or comma

    Keys/Buttons:
    Membrane panel, tactile feel

    Dimensions:
    (L × W × H)
    Panel: 6.00 × 4.95 × 4.00 in (152 × 126 × 102 mm)
    Universal: 9.87 × 4.00 × 9.38 in (248 × 102 × 235 mm)

    Temperature Range:
    Certified: 14 °F to 104 °F (-10 °C to 40 °C)
    Operating: 14 °F to 122 °F (-10 °C to 50 °C)Rating/Material:
    Panel display: stainless steel, NEMA Type 4X, Type 12 and IP69K
    Panel mount controller: Aluminum
    Universal: stainless steel, IP69K

    Weight:
    Panel: 2.5 lb (1.2 kg);
    Universal: 6.5 lb (2.9 kg)

    Warranty:
    Two-year limited

    EMC Immunity:
    10 V/m

    Approvals:
    NTEP 13-080 Class III/IIIL, 10,000d
    Measurement Canada AM-5931C
    OIML R76/2006-A-NL1-18.23 Class III, 10,000d
    EU Test Certificate TC8463
    CE Marked
    cULus Listed (universal)
    cULus Recognized (panel mount)

    • LED display
    • USB device port connects directly to a PC
    • Ethernet TCP/IP polled or continuous polled or continuous, server/client
    • Built-in DIN-rail clips on controller box (panel mount)
    • Display and controller can be separated up to 250 ft (panel mount)
    • Hardware slot for one option card
    • Operator functions through menu key for audit trail, preset tare, accumulator, time & date and setpoints
    • Audit trail tracking for configuration and calibration changes. Password protection for user and configuration changes.
    • 20 setpoints with latched batch engine or unlatched outputs
    • Four onboard digital I/O channels
    • Programmable ticket formats up to 1,000 characters for header text, gross, net, accumulator and setpoints
    • Five-point linearization calibration
    • Local/remote operation
    • Multi-range or multi-interval weighing
    • Filter settings for light, medium and heavy noise

    Options:

    • Analog output
    • Relay board
    • Fieldbus connectivity
    • Dual serial output (v4.00 and newer)
    • 24-channel digital I/O (v4.00 and newer)
    • Truck in/out program for 100 vehicle IDs
    • Adapter plate for converting 310 and 520 panel mounts
    • Panel mount kit for universal enclosure
  • Dimensions 880 Panel-mount Digital Weight Indicator

    A 6.0 in (152 mm) C 4.95 in (126 mm)
    B 4.0 in (102 mm) D 0.58 in (14 mm) BEZEL DEPTH

     