SCT-3300 Signal Conditioning Transmitter
-
Power:
Input: 20 to 28 VDCPower Consumption:
8 WExcitation Voltage:
10 VDC, 170 mA, 6 × 350 ohm load cellsAnalog Signal Input Range:
3.5 to 24 mVAnalog Signal Sensitivity:
0.3 μV/graduation minimum
1.0 μV/graduation recommendedA/D Sample Rate:
300 HzSystem linearity:
± 0.01% full scaleAnalog Output (if equipped):
Opto isolated
0-20 mA, 4-20 mA (max 300 ohm)
0-10 VDC (min 10,000 ohm)Dimensions:
(L × W × H)
4.56 × 3.72 × 2.4 in
(114 × 93 × 60 mm)Temperature & Humidity:
Operating: 14 °F to 122 °F (-10 °C to 50 °C)
Humidity: 85% non-condensingRating/Material:
DIN rail mount: NEMA Type 1Weight:
0.5 lb (0.2 kg)Warranty:
One-year limitedApprovals:
UKCA Marked -
- Powers up to six (350 ohm) load cells in parallel
- Analog amplifier and transmitter
- Analog output: 0-20 mA, 4-20 mA, 0-10 V
- Mounting on Omega/DIN rail for back panel or junction box
-
Booklet SCT-3300
Do you have any questions?
Call us +38 (0800) 301 770
Call us +38 (0800) 301 770
or leave a request and our manager will contact you