  • Power:
    Input: 20 to 28 VDC

    Power Consumption:
    8 W

    Excitation Voltage:
    10 VDC, 170 mA, 6 × 350 ohm load cells

    Analog Signal Input Range:
    3.5 to 24 mV

    Analog Signal Sensitivity:
    0.3 μV/graduation minimum
    1.0 μV/graduation recommended

    A/D Sample Rate:
    300 Hz

    System linearity:
    ± 0.01% full scale

    Analog Output (if equipped):
    Opto isolated
    0-20 mA, 4-20 mA (max 300 ohm)
    0-10 VDC (min 10,000 ohm)

    Dimensions:
    (L × W × H)
    4.56 × 3.72 × 2.4 in
    (114 × 93 × 60 mm)

    Temperature & Humidity:
    Operating: 14 °F to 122 °F (-10 °C to 50 °C)
    Humidity: 85% non-condensing

    Rating/Material:
    DIN rail mount: NEMA Type 1

    Weight:
    0.5 lb (0.2 kg)

    Warranty:
    One-year limited

    Approvals:
    UKCA Marked

    • Powers up to six (350 ohm) load cells in parallel
    • Analog amplifier and transmitter
    • Analog output: 0-20 mA, 4-20 mA, 0-10 V
    • Mounting on Omega/DIN rail for back panel or junction box
  • Booklet SCT-3300