SCT-1100 Signal Conditioning Transmitter
General information
Total Control in a Compact Package
The ideal solution for PLC systems which require weight data from a scale, Rice Lake’s SCT signal transmitters offer maximum control without the additional cost or space required of a traditional weight indicator.
These multi-function transmitters have a compact design while presenting the same signal-conditioning functions.
Utilized as an independent or dependent four-channel digital junction box, the SCT-1100 allows for the direct reading and diagnosis of each individual connected load cell or summed as a whole.
Find out the price or get a consultation
-
Power:
12/24 VDCPower Consumption:
70 mA min to 100 mA maxExcitation Voltage:
5VDC, 120 mA, 8 × 350 ohm load cellsAnalog Signal Input Range:
± 39 mVAnalog Signal Sensitivity:
0.3 μV/graduation minimumA/D Sample Rate:
Four channel A/D 24-bit sigma-delta conversion, up to 200 conv. /sec. auto selectResolution:
Internal: 1,500,000 counts
Display: 800,000Digital I/O:
Two inputs: 12/24 VDC
Two outputs:150 mA 48 VAC/ 150 mA 60 VDCSerial Ports:
Modbus RTU or ASCII selectable/bidirectional
(both ports)
(1) RS-485 for connection to a PC or weight repeater
(1) RS-232 for connection to a PC or printerAnalog Output (if equipped):
Opto isolated, 16-bit
0 to 20mA, 4 to 20mA (Maximum 350 ohm)
0 to 5VDC, 0 to 10VDC (Minimum 10,000 ohm)Annunciators:
Net, center of zero, stabilityDisplay:
Six-digit (10 mm), red LEDKeys/Buttons:
Five key, membrane panel, tactile feel Zero (Down), Tare (Up), Mode (Right), Print (Enter), C (On/Off)Dimensions:
(L × W × H)
4.17 × 3.54 × 2.28 in
(106 × 90 × 58 mm)Temperature:
5 °F to 104 °F (-15 °C to 40 °C)Humidity:
85% non-condensingRating/Material:
Enclosure: NEMA Type 4, plastic
Clear cover: six PG9 cord gripsWarranty:
One-year limitedApprovals:
NTEP 20-046
Measurement CanadaAM-6165C
OIML R76/2006-A-GB1-19.17
UKCA Marked
cULus Listed -
- Up to four independent scales or four load cell inputs
- Quick menu for real and theoretical calibration
- Red LED display
- DIN rail mountable
- Configurable calibration and setup parameters from keyboard
- Calibration using linearization points
- Reading of the net, gross and tare weights, clearing, semi-automatic and pre-settable tare, scale switch, setting of outputs application thresholds
- Diagnostic information via serial port, message display, printing, setting of APW in counting mode, digital input for key press
- Modbus RU or ASCII protocol
- Easy configuration with Rice Lake Tools software
-
Booklet SCT-1100