SCT-10 Signal Conditioning Transmitter

General information


Maximum Control, Miniature Size

For PLC systems that require weight data from a scale, Rice Lake’s compact SCT-10 transmitter delivers equivalent signal-conditioning function without the cost or bulk of a full-size weight indicator/controller.

Rice Lake’s SCT-10 is DIN-rail mountable within a cabinet or control panel, where they convert a scale’s load cell signal to serial or analog output. Technicians and operators find the analog output signal particularly useful for monitoring hopper filling and discharge. Unlike many other signal transmitters, Rice Lake SCTs have their own integrated display, with annunciators for unit and weighing status, and push buttons or toggle switch and digital rotary for zero, tare and setpoint entry—ultimately simplifying scale setup, calibration and operation.

Find out the price or get a consultation

  • Power:
    Input: 12 to 24 VDC

    Power Consumption:
    5 W

    Excitation Voltage:
    5VDC, 120mA, 8 × 350 ohm load cells

    Analog Signal Input Range:
    +/- 19.5 mV

    Analog Signal Sensitivity:
    0.3 μV/graduation minimum
    1.0 μV/graduation recommended

    A/D Sample Rate:
    80 Hz

    Resolution:
    Internal: 16,000,000 counts
    Display: 999,999

    System Linearity:
    ± 0.01% full scale

    Digital I/O:
    2 inputs 5-24VDC, 2 outputs
    24 VDC/60 mA
    N.O. or N.C. (solid state)

    Communication Ports
    RS-485 or RS-232 simplex supports up to 115,200 bps

    Analog Output:
    Optoisolated, 16 bit
    0-20 mA, 4-20 mA (max 300 ohm)
    0-10 VDC, 0-5 VDC, -10 to 10 VDC, 5 to 5 VDC, (min 10 k ohm)

    Annunciators:
    Net, center of zero, stability, KG, G, LB

    Display:
    0.3 in (8 mm), six-digit, 7 segment LED

    Keys/Buttons:
    4-key membrane panel, tactile feel
    Zero, Tare, Print, Menu, Escape,
    Left and Up Navigation, Enter

    Dimensions:
    (L × W × H)
    DIN Rail Mount: 4.84 × 3.62 × 1.96 in (123 × 92 × 50 mm)
    Enclosure: 6.69 × 5.51 × 3.74 in (170 × 140 × 95 mm)

    Temperature & Humidity:
    Operating Temperature: -4 °F to 140 °F (-20 °C to 60 °C)
    Humidity: 85% non-condensing

    Rating/Material:
    DIN rail mount: NEMA Type 1
    Enclosure: NEMA Type 4/IP67, plastic
    Clear cover: six PG9 cord grips

    Weight:
    1 lb (0.5 kg)

    Warranty:
    One-year limited

    Approvals:
    cULus Recognized

    • Converts digital weight to analog output
    • Sums four input channels in parallel
    • Theoretical calibration, real-weigh calibration, linearity calibration
    • Push-button or preset tare
    • Full-scale analog output with zero setting and PLC correction of analog signal
    • Displays weight, configuration, calibration and error conditions
    • DIN-rail mounting, suitable for back panel
    • Two digital inputs, two digital outputs
    • Supports ASCII or MODBUS-RTU protocols