Load cell DEF
General information
S-type load cells are applied for carrying out of weighing of loads in construction of crane scales as well as in overhead systems; at the same time resilient member with resistive-strain sensors operate for tension. In case of crane scales these are mobile decisions, weighing technology consists in hanging of loads by load gripper of scales; after it is carried out lifting of load and fixation of weight readings.
Find out the price or get a consultation
-
4 wires:
- Exciter (+) Red
- Exciter (-) Black
- Impulse (+) Green
- Impulse (-) White
Rated load 50, 100, 150, 200, 250, 300, 500, 750 kg Insulation resistance ≥5000 mΩ 1,1.5,2,3,5 t Operating temperature rated range -10~+ 40ºС Accuracy class 0.03˛ 0.05 Temperature service range -30~+ 70ºС Non-linearity ± 0.03% F.S ± 0.05% F.S Safety load limit 150% F.S Hysteresis error ±0.03% F.S Breaking load 200% F.S Creep (30min) ±0.02% F.S Excitation rated range 10~12 V DC TC ZERO ±0.02% F.S/10ºС Protection class IP65/ IP68 TC INTERVAL ±0.02% F.S/10ºС Material Alloyed steel Input resistance 400±20Ω Stainless steel Output resistance 352±3Ω Cable Length = 5 m -

Do you have any questions?
Call us +38 (0800) 301 770
Call us +38 (0800) 301 770
or leave a request and our manager will contact you